equipment proficiency check or E . P .

00:17.137 --> 00:19.910
C . For the pro pack . MD defibrillator

00:19.920 --> 00:21.920
should take no longer than the time

00:21.920 --> 00:24.760
specified by the instructor evaluation

00:24.760 --> 00:26.593
will be based on your ability to

00:26.593 --> 00:28.538
perform the appropriate pre flight

00:28.538 --> 00:31.080
procedure verbalized the unit's power

00:31.080 --> 00:33.380
requirements , battery time and

00:33.380 --> 00:36.070
recharge time . Check the unit's power

00:36.070 --> 00:39.580
and charge status , verify ready for

00:39.580 --> 00:43.020
use indicator , set noninvasive blood

00:43.020 --> 00:45.187
pressure for an appropriate interval .

00:45.240 --> 00:47.420
Yeah . Cycle the blood pressure Cuff

00:47.430 --> 00:50.800
one time , identify the appropriate

00:50.800 --> 00:53.700
placement of electrodes for 12 lead EKG

00:54.940 --> 00:58.550
obtain a 12 lead ecg kg and

00:58.550 --> 01:01.210
identify cardiac rhythms , verbalizing

01:01.210 --> 01:02.766
appropriate medications and

01:02.766 --> 01:04.988
demonstrating use of electrical therapy

01:05.330 --> 01:09.250
as per A CLS guidelines for lethal

01:09.250 --> 01:11.650
rhythms such as ventricular tachycardia

01:11.860 --> 01:15.710
and ventricular fibrillation . Take a

01:15.710 --> 01:17.660
cardiac rhythms such as atrial

01:17.660 --> 01:20.170
fibrillation , atrial flutter and

01:20.170 --> 01:23.990
symptomatic tachycardia and brady

01:23.990 --> 01:26.760
cardiac rhythms such as 1st , 2nd and

01:26.760 --> 01:28.890
3rd degree atrial ventricular blocks

01:28.970 --> 01:30.750
and severe sinus bradycardia ,

01:33.840 --> 01:34.840
two minutes .

01:36.460 --> 01:38.860
Yeah .

01:40.240 --> 01:43.360
Perform the appropriate pre flight

01:43.360 --> 01:46.760
procedure for the pro pack M . D . Look

01:46.760 --> 01:49.340
for both the yellow be met and orange .

01:49.350 --> 01:51.850
P . M . I . A . E . Certification label

01:52.940 --> 01:55.107
verbalized that the power requirements

01:55.107 --> 01:57.920
for the pro pack M . D . R . 100 to 240

01:57.920 --> 02:01.770
volts A . C . At 50 to 60 hertz or 100

02:01.770 --> 02:04.830
to 115 volts A . C . At 400 hertz .

02:04.840 --> 02:08.480
The battery takes four hours to charge

02:08.490 --> 02:10.580
and will last for six hours with 10

02:10.580 --> 02:12.830
shocks at 200 jewels ,

02:14.510 --> 02:16.677
inspect the monitor and cables for any

02:16.677 --> 02:19.970
sign of damage or disrepair and check

02:19.970 --> 02:22.510
the front led to see if the monitor is

02:22.510 --> 02:25.430
charging and plugged into power . Check

02:25.430 --> 02:27.319
the charge status of the attached

02:27.319 --> 02:29.208
battery by pressing the indicator

02:29.208 --> 02:32.140
button on the battery . Finally turn

02:32.140 --> 02:34.251
the unit on , confirmed that the self

02:34.251 --> 02:36.362
test has been passed and that the red

02:36.362 --> 02:38.870
no symbol has turned to a black octagon

02:38.880 --> 02:42.750
on the R . F . U . Indicator . After

02:42.750 --> 02:44.790
completing Preflight . Set up

02:44.790 --> 02:46.679
noninvasive blood pressure for an

02:46.679 --> 02:47.679
appropriate

02:47.679 --> 02:53.060
interval .

03:00.840 --> 03:03.620
Next demonstrate how to manually cycle

03:03.620 --> 03:07.320
the bp cuff . Once Next obtain a 12

03:07.320 --> 03:10.060
lead ecg kg . Start by verbalizing

03:10.060 --> 03:12.370
appropriate E K . G . Lead placement as

03:12.370 --> 03:16.170
follows . The one is placed at right

03:16.170 --> 03:18.750
sternal border , 4th intercostal space .

03:19.540 --> 03:21.900
V two is placed at the left sternal

03:21.900 --> 03:24.540
border . 4th intercostal space . Yeah ,

03:25.740 --> 03:28.250
the forest placed mid class , vehicular

03:28.260 --> 03:29.860
fifth intercostal space .

03:33.340 --> 03:37.110
Mhm V three goes between Leeds . v .

03:37.110 --> 03:40.920
two and v . four . V . Sixes

03:40.920 --> 03:43.790
mid axillary fifth or sixth intercostal

03:43.790 --> 03:47.480
space . Mhm . B five goes

03:47.480 --> 03:49.536
between the leads . v . four and v .

03:49.536 --> 03:53.490
six . After the 12 lead EKG

03:53.500 --> 03:55.500
leads are attached to the patient ,

03:55.740 --> 03:58.610
Press the 12 lead soft key and press

03:58.610 --> 04:00.820
the 12 lead clipboard to input the

04:00.820 --> 04:03.290
patient's demographics , typically the

04:03.290 --> 04:05.680
patient's and h as given by the

04:05.680 --> 04:06.680
instructor .

04:12.340 --> 04:15.140
Next capture the 12 lead by pressing

04:15.140 --> 04:17.570
the softkey next to the softkey camera

04:17.570 --> 04:19.560
icon .

04:23.240 --> 04:26.990
Next perform proper A CLS interventions

04:26.990 --> 04:28.712
for the following situations .

04:36.140 --> 04:39.040
First , a tacky dysrhythmia is shown .

04:39.660 --> 04:41.549
The patient is currently stable ,

04:41.549 --> 04:43.900
verbally identified the rhythm and

04:43.900 --> 04:47.320
proper interventions , vagal maneuvers

04:47.330 --> 04:50.160
and medication . A dentist seen a first

04:50.160 --> 04:53.850
dose of six mg followed by 12 mg

04:53.860 --> 04:56.480
and another 12 mg . If necessary ,

04:56.490 --> 05:00.420
the patient becomes unstable . You

05:00.420 --> 05:02.531
must now perform the proper steps for

05:02.531 --> 05:05.520
synchronized cardioversion , ensure

05:05.520 --> 05:07.576
that the electrical therapy cable is

05:07.576 --> 05:09.409
connected to the monitor and the

05:09.409 --> 05:09.360
patient

05:12.740 --> 05:15.970
press the sync button on the bottom of

05:15.970 --> 05:18.330
the pro pack M . D . And visualize the

05:18.330 --> 05:20.750
yellow S . Is that accompany the QRS

05:20.750 --> 05:24.560
complexes press button one

05:24.570 --> 05:27.710
to select energy . Typically start at

05:27.710 --> 05:29.960
100 jewels .

05:31.940 --> 05:35.150
Press button to to charge

05:35.160 --> 05:39.150
once fully charged . Clear

05:39.150 --> 05:41.530
the patient . And press and hold button

05:41.540 --> 05:44.570
three or the shock button until you see

05:44.570 --> 05:47.290
a drop in the Q . R . S . Yeah I'm

05:47.290 --> 05:49.520
clear your clear everybody's clear

05:49.530 --> 05:53.290
shocking shock delivered . If the

05:53.290 --> 05:55.401
patient remains in the previous state

05:55.401 --> 05:57.512
and an additional shock is required .

05:57.512 --> 06:00.400
You must press the sync button again to

06:00.400 --> 06:02.678
synchronize cardio over at the patient .

06:02.678 --> 06:05.560
Mhm . Yeah .

06:09.440 --> 06:12.090
You now see a bradycardia rhythm on the

06:12.090 --> 06:14.220
monitor . The patient is currently

06:14.220 --> 06:16.720
stable . You must verbally identify the

06:16.720 --> 06:19.500
rhythm and proper interventions . There

06:19.500 --> 06:21.560
is a wide complex bradycardia

06:22.240 --> 06:25.730
medication is 0.5 mg of atropine .

06:25.850 --> 06:28.870
Every 3 to 5 minutes to a maximum dose

06:28.880 --> 06:31.240
of three mg the patient becomes

06:31.250 --> 06:33.810
unstable . You must now perform the

06:33.810 --> 06:36.550
proper steps for pacing . Press the

06:36.550 --> 06:38.680
Pacer button on the bottom of the pro

06:38.680 --> 06:42.060
pack . MD . The Pacer menu will appear .

06:42.540 --> 06:45.850
First start Pacer and visualize the

06:45.850 --> 06:49.560
blue peas that appear . Mhm .

06:50.440 --> 06:52.900
Next set your rate as given by the

06:52.900 --> 06:56.730
instructor . Then slowly increase the

06:56.730 --> 06:59.730
Pacer output until a QRS is captured

06:59.730 --> 07:03.420
with every blue P . Once you achieve

07:03.420 --> 07:05.820
capture increase the output by 10 to

07:05.820 --> 07:09.050
assure capture . Yeah . Mhm .

07:09.740 --> 07:12.073
Also verify capture by checking a pulse .

07:13.340 --> 07:17.220
Yeah . Mhm . Finally state the

07:17.220 --> 07:19.580
reason for pausing the pacer which is

07:19.580 --> 07:21.469
to check the patient's underlying

07:21.469 --> 07:24.630
rhythm . Mhm . Pause pacer to check

07:24.630 --> 07:25.741
underlying rhythm .

07:28.540 --> 07:29.740
Mhm . Yeah .

07:32.840 --> 07:35.560
Now ventricular tachycardia or

07:35.560 --> 07:37.782
ventricular fibrillation will appear on

07:37.782 --> 07:40.004
the monitor . You check for a pulse and

07:40.004 --> 07:42.060
find that the patient is pulseless .

07:42.060 --> 07:44.990
Immediately advise someone to start cpr

07:45.000 --> 07:46.833
and perform the proper steps for

07:46.833 --> 07:49.750
defibrillation . Start cpr press button

07:49.750 --> 07:52.970
one to select energy . Select the

07:52.970 --> 07:56.590
proper defib dose typically between 120

07:56.600 --> 07:59.750
and 200 jewels . Press button to to

07:59.750 --> 08:02.960
charge once fully charged . Clear the

08:02.960 --> 08:05.520
patient and press button three or the

08:05.520 --> 08:08.000
shock button . I'm clear your clear

08:08.000 --> 08:10.690
everybody's clear , shocking shock

08:10.690 --> 08:12.960
delivered state . To resume Cpr ,

08:13.440 --> 08:16.280
resume cpR . You must also verbalize

08:16.280 --> 08:18.960
proper a CLS medication administration ,

08:19.440 --> 08:22.940
one mg , epinephrine every 3 to 5

08:22.940 --> 08:26.070
minutes and 300 mg , amiodarone for the

08:26.070 --> 08:29.020
first dose and 150 mg for the second

08:29.020 --> 08:32.950
dose . Finally verbalize how often to

08:32.950 --> 08:35.061
check for a pulse . Check for a pulse

08:35.061 --> 08:37.228
every two minutes or every five cycles

08:37.228 --> 08:39.820
of cpR . This completes the equipment

08:39.820 --> 08:42.098
proficiency . Check for the pro pack M .

08:42.098 --> 08:43.340
D . Yeah .